# Experimental measurements and attribution

**Panasonic NCR18650B discharge.** Raghav Sai Thiagarajan, Anthony Concepción, Deepti Tewari, Judith A. Jeevarajan, Vinay Premnath and Venkat R. Subramanian, “Modeling the Effect of Over-discharge Cycling on Li-ion Batteries,” Journal of The Electrochemical Society 172 (2025) 050534. © 2025 The Authors. The publisher identifies the article and figures as CC BY 4.0. BatterMachine digitized experimental points from Figures 4b, 4d and 5c, converted pixel coordinates to seconds, volts and degrees Celsius, and rounded the readings. The browser’s empirical voltage fit and first-order thermal model are original implementations. Its coefficients were estimated from those digitized observations. [Original paper](https://doi.org/10.1149/1945-7111/add775) · [Author-hosted paper with licence](https://sites.utexas.edu/maple/wp-content/uploads/sites/4803/2025/06/105-Thiagarajan_2025_J._Electrochem._Soc._172_050534.pdf) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)

The discharge model applies to the reported 1.625 A run. Three windows were excluded from coefficient fitting, 2,700–3,300 s, 6,100–6,500 s and 7,080 s onward. Surface temperature was measured near the positive terminal. The source panels have independent clocks and inconsistent specimen labels. The published raster represents roughly 14 seconds per horizontal pixel in both panels. The voltage endpoint uses the specified 1.5 V cutoff and the time indicated by the last low-voltage markers. Changing the reporting threshold restricts the comparison to part of that source protocol.

**Prismatic LFP overcharge.** Jun Shen, “overcharge-induced Thermal Runaway data in Prismatic Lithium Iron Phosphate Battery,” Mendeley Data V1 (2025). The deposited dataset is CC BY 4.0. BatterMachine selected the 32 A and 40 A files, changed timestamps to elapsed seconds from the first reading, and retained recorded voltage and upper and middle surface temperatures. Empty measurements remain missing. Nominal current identifies the file, and delivered current was not measured in these channels. The voltage channel can reflect the source after electrical contact changes. [Original dataset](https://doi.org/10.17632/8zjttd77my.1) · [Dataset licence declaration](https://data.mendeley.com/datasets/8zjttd77my/1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)